HMS Slot Machines Tilt Codes |
CODE |
DESCRIPTION |
DIRECTIONS |
-0- |
Power On (789,270,-0-) | Normal Power on Code |
--_ | Stair Case dashes (high middle low dashes) | Free Spin (able to pull handle with no coins in) Shorted Handle coil driver (Interface board) or stuck mechanism |
X0- |
Bad Voltage High | The detector for the reel is shorted or no connection |
X1- |
Flaky 'A' feedback | Detector is bad or poor connection |
X2- |
Flaky 'B' feedback | Detector is bad of poor connection |
X3- |
Spinning Slow | Fix cause for slow spin (usually rubbing or bearings need oil) |
X4- |
Spinning Fast | Never seen this (put it in the code anyway) |
X5- |
Bad Detector (both feedbacks high or both low) | Replace Detector |
X6- |
Failed Home (could locate the home position) | Wrong Firmware of Blocked holes on the Indexing disc |
X7- | bad feedback at verify | Detector alignment or replace detector |
X8- | Both detectors not going low | Replace Detector |
X9- | Failed to stop on Goal | Clean/Lubricate stop mechanism pivot points. Missing springs? |
888 |
Not Documented | Contact HMS Electronics Technical Support if you encounter this. |
999 |
Not Documented | Contact HMS Electronics Technical Support if you encounter this |
Note: The 'X' typically indicates the reel number (reel 1 or reel 2 or reel 3 or reel 4)
On Payout Flashing '0' No coins out were detected. Adjust coin out switch or clean connector contacts:
On Payout Flashing 'number'. Ran out of coins or hopper stopped or flaky feedback from the coin out switch.